This chapter contains the following topics:
Components
The following figure shows an empty Cisco UCS X9508 server chassis and identifies the front, back, and vertical node slots, and horizontal module slots.
![]() Note | Before you remove or install components, please ensure that all software applications are shut down and management software is in a good state. |
![]() Note | Whenever you remove a module from the chassis for an extended period of time, always replace the module with the appropriate blank panel. Failing to do so can result in heating and EMI issues. Blank panels can be ordered from Cisco Systems. |
![Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (3) Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (3)](https://i0.wp.com/www.cisco.com/c/dam/en/us/td/i/300001-400000/300001-310000/308001-309000/308908.jpg)
The side of the chassis has no handles because the chassis is heavy, and not intended to be lifted unless you are using a scissor lift or another type of mechanical lift device to bear the weight of the chassis. The right side of the chassis has the PSU Keying Bracket which enforces proper PSU orientation as well as proper PSU type.
![Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (4) Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (4)](https://i0.wp.com/www.cisco.com/c/dam/en/us/td/i/300001-400000/300001-310000/308001-309000/308906.jpg)
The left side of the chassis has no handles.
![Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (5) Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (5)](https://i0.wp.com/www.cisco.com/c/dam/en/us/td/i/300001-400000/300001-310000/308001-309000/308905.jpg)
1 | Node slots (8). Each slot is numbered horizontally below each slot. Compute nodes and PCIe nodes can be inserted vertically and connect to the power socket for each slot. | 2 | PSU bays (6). Each PSU bay is numbered vertically to the right of the bay. Each PSU bay is keyed so that the PSU inserts only one way. |
The front of the chassis accepts up to 8 Cisco UCS X210c M6 compute nodes with connections for power and basic signaling through the per-slot socket connections to the midplane. The front of the server chassis also hosts up to 6 PSUs providing power to the chassis power plane through internal connectors. PSUs are numbered one through six with PSU bay one as the topmost slot and PSU bay 6 on the bottom.
![]() Caution | Any node slot that is not occupied must have a compute node blank panel (UCSX-9508-FSBK) installed. |
![Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (7) Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (7)](https://i0.wp.com/www.cisco.com/c/dam/en/us/td/i/300001-400000/300001-310000/308001-309000/308907.jpg)
1 | Power Entry Modules (2) Each PEM houses three IEC 320 compatible C20 power inlets inlet facility power. | 2 | IFM slots (2) |
3 | Fan Bays (4) Fans are numbered 1 through 4 with fan 1 as the leftmost. | 4 | Expansion Slots (2) |
The top of the chassis rear contains up to two Intelligent Fabric Modules (IFMs). Power connections and minimal signaling are supported through the per-slot socket connections to the midplane. Three vertically stacked Power Entry Module (PEM) connectors are also supported, which correspond with PSUs one through three, with PSU one as the topmost connector.
The middle of the chassis rear houses up to four fan modules and power is supplied through one connector per fan module. Fans are numbered from one to four with Fan 1 being the leftmost fan, and Fan 4 being the right most.
The bottom of the chassis rear houses two active fan modules. Power connections and minimal signaling are supported through the per-slot socket connections to the midplane. Three vertically stacked PEM connectors are also supported, which correspond with PSUs four through six, with PSU four as the topmost connector.
![]() Note | Before you install, operate, or service the system, see the Regulatory Compliance and Safety Information for Cisco UCS for important safety information. |
![]() Warning | IMPORTANT SAFETY INSTRUCTIONS This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. Use the statement number provided at the end of each warning to locate its translation in the translated safety warnings that accompanied this device. Statement 1071 SAVE THESE INSTRUCTIONS |
![]() Warning | This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security. Statement1017 |
![]() Warning | Only trained and qualified personnel must be allowed to install, replace, or service thisequipment. Statement1030 |
Cisco UCS 9108 25G IFM Components
The Cisco UCS 9108 25G Intelligent Fabric Module has the following board-level components.
![Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (12) Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (12)](https://i0.wp.com/www.cisco.com/c/dam/en/us/td/i/300001-400000/300001-310000/308001-309000/308929.jpg)
1 | Fans (UCSX-RSFAN=), three, which are numbered 1 through 3 starting with the left fan. | 2 | One M.2 mini storage module slot |
3 | SFP28 Optical Ports. Ports are arranged in two groups of four physical ports. Port number 1 is the left port in this group, and port number 4 is the right port in the group. | 4 | SFP28 Optical Ports. Ports are arranged in two groups of four physical ports. Port number 5 is the left port in this group, and port number 8 is the right port in the group. |
5 | IFM ejector handles, left and right |
Cisco UCS 9108 100G IFM Components
![Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (13) Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (13)](https://i0.wp.com/www.cisco.com/c/dam/en/us/td/i/300001-400000/300001-310000/308001-309000/308930.jpg)
1 | Fans, (UCSX-RSFAN=), three, which are numbered 1 through 3 starting with the left fan | 2 | One M.2 mini storage module slot |
3 | QSFP28 Optical Ports. Ports are arranged in two groups of four physical ports. Ports are stacked in vertical pairs, with two ports in each vertical port stack. Port number 1 is the top port of the left port pair in this group, and port number 3 is the top port of the right port pair in the group. | 4 | QSFP28 Optical Ports. Ports are arranged in two groups of four physical ports. Ports are stacked in vertical pairs, with two ports in each vertical port stack. Port number 5 is the top port in the left port pair of this group, and port number 7 is the top port in the right port pair of the group. |
5 | IFM ejector handles, left and right |
Cisco UCS X9416 Fabric Module Components
The Cisco X9416 module (UCSX-F-9416) has the following components.
![Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (14) Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (14)](https://i0.wp.com/www.cisco.com/c/dam/en/us/td/i/500001-600000/540001-550000/540001-541000/540442.jpg)
1 | Fans (UCSX-RSFAN=), three, which are numbered 1 through 3 starting with the left fan | 2 | Module Ejector Handles, Left and Right |
Cisco UCS X-Fabric Module Blank Components
The Cisco X-Fabric Module Blank (UCSX-9508-RBLK) has the following components.
![Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (15) Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (15)](https://i0.wp.com/www.cisco.com/c/dam/en/us/td/i/300001-400000/300001-310000/308001-309000/308926.jpg)
1 | Fans (UCSX-RSFAN=), three, which are numbered 1 through 3 starting with the left fan | 2 | Module Ejector Handles, Left and Right |
Installing and Removing a Compute Node Blank
The UCS X9508 supports up to 8 compute nodes, with a minimum configuration of one compute node. If compute node slots do not contain a compute node, you must install a compute node blank.
Use these procedures to replace a compute node blank:
-
Installing a Compute Node Blank
-
Removing a Compute Node Blank
Removing a Compute Node Blank
Do not operate the server chassis with an empty compute node slot. Fill any empty compute node slots with either a blank (UCSX-9508-FSBK) or a compute node.
Use this task to remove a compute node blank.
Procedure
Step1 | Grasp the compute node by the finger holds. ![]() |
Step2 | Pull the compute node blank towards you until it is completely removed from the chassis. ![]() |
What to do next
Choose the appropriate option:
-
Installing a Compute Node
-
Installing a Compute Node Blank
Installing a Compute Node Blank
If you remove a compute node, and you will not be installing another compute node, you must install a compute node blank. Do not operate the server with an empty compute node slot. The minimum configuration is 1 installed compute node, so in this configuration you need 7 module blanks installed.
Compute node blanks are interchangeable within the same chassis or other chassis.
Use this task to install a compute node blank
Procedure
Step1 | Grasp the blank by the finger holds. | ||
Step2 | Hold the module blank vertically and align the module blank with the slot.
. | ||
Step3 | Keeping the compute node blank vertical, slide it into the slot until the blank is flush with the face of the chassis. ![]() |
Installing and Removing a Compute Node
The Cisco UCS X9508 server chassis supports full-height compute nodes. For details, see the Installation and Service Note for your compute nodes. See http://www.cisco.com/en/US/products/ps10280/prod_installation_guides_list.html
![]() Caution | When working with the compute nodes, handle them carefully to avoid damage to the modules, connectors, and pins. |
Installing a Compute Node
Use this task to install a compute node in an empty slot.
![]() Caution | When working with the compute nodes, handle them carefully to avoid damage to the modules, connectors, and pins! Make sure that the modules are level during insertion and slide them into the chassis slowly. |
Before you begin
Compute nodes are shipped with the ejector handles closed and locked. Each compute node has a release button in the center of the node that releases the ejectors from the locked position.
Procedure
Step1 | Press the release button at the center of the compute node faceplate to release the ejectors.
| ||
Step2 | Holding the compute node vertical, align it with the empty module bay in the chassis. ![]() | ||
Step3 | Keeping the compute node vertical, slowly slide it into the chassis. As the compute node is almost completely installed, you might feel some resistance. This resistance is normal. It occurs because the connectors at the rear of the compute node contacts the connector on the inside of the chassis.
| ||
Step4 | When the compute node is almost completely installed, grasp the ejector handles and arc them toward each other. This step seats the compute node into the connector. The compute node should power up.
| ||
Step5 | Push the ejectors until they are parallel with the face of the compute node. When the compute node is completely installed, the retention latches at the end of each handle click into place. |
Removing a Compute Node
Use this task to remove a compute node.
![]() Caution | When working with the compute nodes, handle them carefully to avoid damage to the modules, connectors, and pins! Make sure that the modules are level during removal and slide them out of the chassis slowly. |
Before you begin
Do not operate the server with an empty compute node slot. If you will not be installing a compute node in an empty slot, install a compute node blank to cover the empty slot.
Procedure
Step1 | Press the release button at the center of the compute node faceplate to disengage the ejector handles. | ||
Step2 | Grasp the ejector handles and pull them outward so that they arc vertically away from each other. While moving the compute node handles, you might feel some resistance. This resistance is normal. It occurs because the connectors at the rear of the compute node are unseating from the corresponding sockets in the chassis. Also, when the compute node disconnects from the midplane, the server powers off. ![]() | ||
Step3 | Grasp the compute node handles and slide the compute node partially out of the chassis. Make sure to keep the compute node vertical while removing it.
| ||
Step4 | Place your other hand underneath the compute node to support it and slide the compute node completely out of the chassis. |
What to do next
Fill the empty compute node slot. Go to the appropriate option:
-
Installing a Compute Node
-
Installing a Compute Node Blank
Installing and Removing Power Supplies
![]() Note | The power supplies are keyed to work only with their respective power expansion module (PEM), depending on the chassis version. |
When in installing and removing power supplies, make sure that the minimum number of power supplies are active before replacing the other PSUs. For example, in a 3+3 grid power configuration, at least 3 PSUs must be active before replacing the other 3 units one at a time per grid.
The PSUs are installed vertically along the side of the chassis.
![Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (26) Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (26)](https://i0.wp.com/www.cisco.com/c/dam/en/us/td/i/300001-400000/300001-310000/308001-309000/308924.jpg)
PSU Population Rules
When you install PSUs, they must be equally divided into top and bottom PSU slots to ensure redundancy. See the following PSU population rules.
-
For 2 PSUs: Install a PSU in slots 1 and 4. This is the minimum supported config.
-
For 3 PSUs: Install a PSU in slots 1, 2, and 4.
-
For 4 PSUs: Install a PSU in slots 1, 2, 4, and 5.
-
For 5 PSUs: Install a PSU in slots 1, 2, 3, 4, and 5.
-
For 6 PSUs: Install a PSU in all slots.
Any slots that do not contain a PSU must be covered by a PSU blank.
Installing a Power Supply
The Cisco UCS X9508 AC PSU does not have a discrete power switch. It powers on immediately when it is successfully connected to the power midplane. When installing a PSU, you must comply with the PSU population rules. See PSU Population Rules.
PSUs are hot swappable with a minimum population of two in the chassis to provide redundancy. PSUs are interchangeable and none are reserved through the management software.
![]() Caution | When connecting the chassis to facility power, make sure not to overload the capacity of a PDU or power strip. For example, do not connect all PSUs to one PDU or power strip that is not capable of carrying the total power draw of the chassis. |
Use the following procedure to install the PSUs.
Procedure
Step1 | Grasp the PSU with one hand. | ||
Step2 | Use your other hand to support the PSU, and holding it level, orient it with the PSU bay. The PSU is correctly oriented when the latch is facing you and parallel with the right side of the PSU bay. | ||
Step3 | Holding the PSU level, slide it into the PSU bay.
![]() | ||
Step4 | For each PSU that must be installed, repeat these steps. | ||
Step5 | Verify the power supplies are operating by checking the power supply LEDs. See LED Locations and Interpreting LEDs.
|
Removing a Power Supply
![]() Caution | If you are using the Cisco UCS X9508 server chassis with one power supply, which is a non-redundant power configuration. Removing the power supply will cause the compute nodes and chassis to shut down. If you are using more than two power supplies, and you remove one of them (the minimum supported power configuration is 3 PSUs), the servers continue to operate as long as the other power supplies are sufficient to meet the power requirements of the number of compute nodes in the chassis. |
The PSU has a locking latch that secures the PSU in the chassis. You must unlock the latch to remove the PSU. You can expect some resistance as the PSU slides out due to its weight.
Procedure
Step1 | Place your thumb on the PSU locking latch at the vertical fingerhold on the right side of the blank's faceplate and allow your other fingers to rest along the side of the chassis. |
Step2 | Press the latch to unlock the PSU, then pull until it disengages from the power socket inside the chassis. You will feel some resistance initially as the connector at the rear of the PSU unseats from the power socket inside the chassis. |
Step3 | As you slide the PSU out of the chassis, use your other hand to support the PSU. |
Step4 | Install a blank power supply filler panel if the power supply bay is to remain empty. |
What to do next
-
If you will be reinstalling a PSU, go to Installing a Power Supply
-
If you will be installing a PSU blank, go to Installing a PSU Blank.
Replacing a PSU Blank
PSU blanks (UCSX-9508-PSUBK) are interchangeable, but if you will be operating the server chassis without a PSU, the empty bay must be covered with a PSU blank. Replace a PSU blank when you remove a PSU but will not install another PSU in that PSU bay, or when you remove a PSU blank and need to cover the empty PSU bay.
-
Removing a PSU Blank
-
Installing a PSU Blank
Removing a PSU Blank
Use this procedure to remove a PSU blank.
![]() Note | The PSU blank is a small plastic piece. It does not have a locking latch, so it slides out easily. |
Procedure
Step1 | Place your thumb behind the vertical fingerhold on the right side of the blank's faceplate and allow your other fingers to rest along the side of the chassis. |
Step2 | Using your thumb, grasp the PSU blank by the vertical fingerhold and pull the PSU blank straight towards you. The PSU should easily slide out of the chassis. ![]() |
What to do next
Choose the appropriate option:
-
If you are installing a PSU, go to Installing a Power Supply.
-
If you are installing a PSU blank, go to Installing a PSU Blank.
Installing a PSU Blank
The minimum supported power configuration for the UCS X9508 server chassis is three PSUs. If you will be operating the server chassis with an empty PSU bay, it must be covered with a PSU blank (UCSX-9508-PSUBK).
Use this procedure to install a PSU blank.
Procedure
Step1 | Grasp the PSU blank by the vertical finger hold on the right side of the blank's face. |
Step2 | Align the PSU blank so that the word UP is facing up, and the handle is parallel to the right side of the PSU bay. |
Step3 | Insert the PSU blank until its faceplate is flush with the front of the server chassis. ![]() |
Replacing the PSU Keying Bracket
The PSU Keying bracket is attached to the right exterior side of the chassis. The bracket ensures that only the correct type of PSU can be installed, and that the PSU is inserted in correct orientation in the chassis.
Use the following procedures to replace the PSU Keying bracket:
-
Removing the PSU Keying Bracket
-
Installing the PSU Keying Bracket
Removing the PSU Keying Bracket
Use this procedure to remove the PSU Keying bracket.
Before you begin
The chassis must be completely removed from the rack to provide access to the exterior of the chassis where the PSU Keying bracket will be installed.
When the chassis is removed from the rack, make sure that you place the chassis on an ESD-safe workspace, for example, a rubberized mat.
Procedure
Step1 | If you have not already removed the chassis from the rack, do so now. Go to Removing the Chassis from a Rack.
| ||
Step2 | With the chassis in an ESD-safe work area, locate the PSU Keying bracket on the right exterior side of the chassis. | ||
Step3 | Using a T10 screwdriver, remove the six screws that attach the bracket to the chassis. | ||
Step4 | Grasp the PSU keying bracket and detach it from the chassis. | ||
Step5 | Keep the screws and bracket. |
What to do next
Installing the PSU Keying Bracket.
Installing the PSU Keying Bracket
Use this task to install a PSU Keying bracket (UCSX-9508-KEY-AC=).
Procedure
Step1 | With the chassis on an ESD-safe work area, grasp the new PSU Keying Bracket, and align it with right exterior side of the chassis. |
Step2 | Place the bracket against the side of the chassis, aligning the screwholes in the bracket with the screwholes in the chassis. |
Step3 | Insert the 6 screws into the screwholes. |
Step4 | Using a T10 screwdriver, secure the bracket to the chassis by tightening each screw to snug. If you have access to a torque wrench, tighten the screws to 6 in-lb. |
Step5 | Reinstall the chassis:
|
Replacing the Power Entry Modules (PEMs)
The Cisco UCS X9508 chassis contains two power entry modules (PEMs). Each PEM is a grouping of 3 IEC 320 compatible C20 power inlets. One PEM supports PSUs 1 through 3, and one PEM supports PSUs 4 through 6. Each PEM is field replaceable.
Use the following procedures to replace the PEMs:
-
Installing the Power Entry Modules
-
Removing the Power Entry Modules
Installing the Power Entry Modules
Use this procedure to install a PEM.
![]() Note | The following task shows installing both PEMs. If you are installing only one PEM, you will need to tighten only the PEM screw for the replaced PEM, not both screws as shown in the illustrations. |
Before you begin
![]() DANGER | Follow all electrical safety precautions when working with facility power. Failure to do so can result in damage to the equipment or pose a risk of injury or death to personnel. |
Procedure
Step1 | Grasp the PEM and orient it correctly. The PEM is keyed so that you can insert it only one way. |
Step2 | Holding the PEM level, slide it into the PEM slot. You might feel some resistance as the connector on the rear of the PEM meets the connector on the interior of the chassis. |
Step3 | Using a T10 screwdriver, tighten the captive screws which are easily identifiable because they are next to the electrical ground icons on the chassis walls.
|
Step4 | Reinstall the IFMs and expansion modules.
|
Step5 | Reconnect all power cables. |
Removing the Power Entry Modules
PEMs support inlet power to the chassis from the facility. It is a best practice to remove all power from the system when replacing a PEM.
![]() DANGER | Follow all electrical safety precautions when working with facility power. Failure to do so can result in damage to equipment or pose a risk of injury or death to personnel. |
![]() Note | The following task shows removing both PEMs. If you are removing only one PEM, you will need to loosen only the PEM screw for the replaced PEM, not both screws as shown in the illustrations. |
Before you begin
The power entry modules (PEMs) are connected to facility power, so you must disconnect facility power from the PEM that you will be removing.
Procedure
Step1 | Power down all compute nodes. |
Step2 | Remove any power cables that are attached to the PEM. |
Step3 | Remove the IFMs and expansion modules.
|
Step4 | Using a T10 screwdriver, loosen the captive screws that attach the PEM to the chassis. The captive screws are easily identifiable because they are next to the electrical ground icons on the chassis walls.
|
Step5 | Grasp the PEM and slide it out of the chassis. When you remove a PEM, you must replace it with another one. Do not operate the system with an empty PEM slot. ![]() |
What to do next
Install a PEM. Go to Installing the Power Entry Modules.
Installing and Removing a Fan Module
You can hot swap a fan module (UCSX-9508-FAN) without causing an electrical hazard or damage to the system. However, you can only remove one fan module while the system is operating. Removing more than one fan module could cause overheating.
Fan Module Replacement Consideration
While a fan module is absent from the chassis, the pair of compute nodes physically associated with that fan may be throttled to prevent thermal overload. After the fan module is replaced in the chassis, throttling is removed and the associated blades resume normal operation.
To minimize the impact to system performance, do not remove a fan module until a replacement fan module is available. Leaving the fan module out of the chassis for longer durations of time will result in extreme power throttling of the associated compute nodes, but the nodes will not shutdown.
The following table shows the mapping of fan modules to their associated compute nodes.
Fan Module | Compute Node Slots |
---|---|
1 | 7, 8 |
2 | 5, 6 |
3 | 3, 4 |
4 | 1, 2 |
Installing a Fan Module
Procedure
Step1 | Hold the fan module with the handle at the bottom and place your other hand underneath the fan module to support it. | ||
Step2 | Align the fan with the fan bay in the rear of the chassis. ![]() | ||
Step3 | Slide the fan into the chassis until it is flush with the face of the chassis.
When the fan module is almost completely installed, you might feel some resistance. The resistance is normal, and it occurs when the connector at the rear of the fan contacts the corresponding socket inside the chassis. ![]() | ||
Step4 | Listen for the fan to power up and verify that the LED behavior is as expected. See LED Locations and Interpreting LEDs. |
Removing a Fan Module
Procedure
Step1 | Grasp the fan module handle and push down on the release button. ![]() | ||
Step2 | Slide the fan module partially out of the chassis and place your hand underneath it to support it. When the fan disconnects from the midplane, it will power down. | ||
Step3 | Slide the fan completely out of the chassis, making sure to support its weight with your other hand.
|
What to do next
Installing and Removing a Rear Module's Fan
The Cisco UCS X9508 Intelligent Fabric Module (IFM) and X-Fabric Module (XFM) blanks use the same fan (UCSX-RSFAN=), which makes the fans interchangeable between these modules and module blanks. In a typical configuration, there are three fans numbered from one to three.
![]() Note | The fans for IFM and XFMs (UCSX-RSFAN=) are different from the fan modules (UCSX-9508-FAN) that provide cooling and ventilation for the entire server chassis. These two types of fans are not interchangeable. |
Use the following procedures to replace a fan on a Cisco UCS X9508 module or module blank.
-
Installing a Fan for a UCS Intelligent Fabric Module (IFM) or X-Fabric Module (XFM) Blank
-
Removing a Fan for a UCS Intelligent Fabric Module (IFM) or X-Fabric Module (XFM) Blank
Installing a Fan for a UCS Intelligent Fabric Module (IFM) or X-Fabric Module (XFM) Blank
Use this task to install the fan (UCSX-RSFAN=) for a UCS Intelligent Fabric Module (IFM) or X-Fabric Module (XFM) Blank.
Procedure
Step1 | Align the fan correctly.
|
Step2 | Press down evenly on the fan until it is fully seated. Make sure the fan is level while you're installing it. You will feel the fan click into place when it is correctly seated on the module or module blank. |
Removing a Fan for a UCS Intelligent Fabric Module (IFM) or X-Fabric Module (XFM) Blank
Use the following procedure for removing a fan (USCX-RSFAN=) from a UCS Intelligent Fabric Module (IFM) or X-Fabric Module (XFM) Blank.
Procedure
Step1 | Grasp the fan by the tabs on each long side wall. |
Step2 | Pull the fan straight up. This step disconnects the fan from the power connector and lifts the fan off of the board. ![]() |
What to do next
Insert a fan module. Go to Installing a Fan for a UCS Intelligent Fabric Module (IFM) or X-Fabric Module (XFM) Blank.
Installing and Removing an Intelligent Fabric Module
Intelligent Fabric Modules (IFMs) install in the rear of the chassis. They are always deployed in pairs, and the minimum IFM configuration for each UCS X9508 is two. For more information, see Intelligent Fabric Modules.
![]() Caution | When working with the IFMs, handle them carefully to avoid damage to the modules, connectors, and pins. |
Use the following procedures to replace an IFM:
-
Installing an Intelligent Fabric Module
-
Removing an Intelligent Fabric Module
Installing an Intelligent Fabric Module
Intelligent Fabric Modules (IFM) must be deployed in pairs, so there are no IFM module blanks that can be installed.
![]() Caution | When working with the IFMs, handle them carefully to avoid damage to the modules, connectors, and pins! Make sure that the modules are level during insertion and slide them into the chassis slowly. |
Procedure
Step1 | If the IFM has a cable management tray, remove it. See Removing the Cable Management Tray. | ||
Step2 | Swing the ejector handles to the open position. | ||
Step3 | Placing one hand underneath the IFM, align the module with the empty IFM slot on the rear of the chassis. ![]() | ||
Step4 | Holding the IFM level, slide it almost all the way into the chassis until you feel some resistance. This resistance is normal. It occurs when the connectors at the rear of the IFM contact the socket inside the chassis.
| ||
Step5 | Grasp each of the ejector handles, and keeping them level, slowly arc them inward toward the chassis. This step seats the IFM connectors into the sockets on the midplane.
| ||
Step6 | Push the ejector handles until both are parallel with the face of the IFM. Make sure the ejector latch is fully inserted in the front panel | ||
Step7 | If the IFM has a cable management tray, attach it. See Installing the Cable Management Tray. |
Removing an Intelligent Fabric Module
Intelligent Fabric Modules (IFM) must be deployed in pairs, so when you remove one, you must insert another IFM in its place.
![]() Caution | When working with the IFMs, handle them carefully to avoid damage to the modules, connectors, and pins! Make sure that the modules are level during removal and slide them out of the chassis slowly. |
Procedure
Step1 | If the IFM has a cable management tray, remove it. See Removing the Cable Management Tray. | ||
Step2 | Using your fingers, pinch the interior end of both handles to disengage the ejector latch. This step unlocks the module handles so that they can move. ![]() | ||
Step3 | Keeping the modules handles level, pull them towards you so that they arc away from the chassis. You might feel some resistance as the IFM disconnects from the socket inside the chassis. | ||
Step4 | Slide the module about halfway out of the chassis, then place your other hand underneath the IFM to support it.
| ||
Step5 | Continue sliding the IFM out of the chassis until it is completely removed. ![]() |
What to do next
Insert an IFM. Go to Installing an Intelligent Fabric Module
Installing and Removing an X-Fabric Module
X-Fabric Modules, such as the Cisco UCS X9416, are required when the UCS X9508 chassis contains one or more pairs of X-Series compute nodes and X-Series PCIe Nodes, such as the Cisco UCS X440p PCIe node. For more information, see X-Fabric Modules.
For information about the Cisco UCS X440p PCIe Node, go to the Cisco UCS X440p PCIe Node Hardware Installation and Service Guide.
![]() Caution | Because both XFMs connect to all slots on the front of the server chassis, all pairs of compute nodes and PCIe nodes must be powered off before removing or inserting XFMs. |
![]() Caution | Although the Cisco UCS X-Fabric Modules can be removed, it is a best practice to leave them installed even during chassis installation. |
Use the following procedures to install or remove an X-Fabric Module.
-
Removing an X-Fabric Module
-
Installing an X-Fabric Module
Removing an X-Fabric Module
Use the following procedure to remove a Cisco UCS X-Fabric Module.
![]() Caution | When working with the XFMs, handle them carefully to avoid damage to the modules, connectors, and pins! Make sure that the modules are level during removal and slide them out of the chassis slowly. |
Before you begin
![]() Caution | Make sure that all pairs of compute nodes and PCIe nodes are completely powered off before removing an X-Fabric Modle (XFM). |
Procedure
Step1 | Using your fingers, pinch the interior end of both handles to disengage the ejector latch. This step unlocks the module handles so that they can move. | ||
Step2 | Keeping the modules handles level, pull them towards you so that they arc away from the chassis.
You might feel some resistance as the module disconnects from the socket inside the chassis. ![]() | ||
Step3 | Keeping the module level, slowly slide the module about halfway out of the chassis, then place your other hand underneath the module to support it. | ||
Step4 | Continue sliding the module out of the chassis until it is completely removed. ![]() |
What to do next
Insert an X-Fabric Module. Go to Installing an X-Fabric Module
Installing an X-Fabric Module
Use the following procedure to install a Cisco UCS X-Fabric Module.
![]() Caution | When working with the XFMs, handle them carefully to avoid damage to the modules, connectors, and pins! Make sure that the modules are level during installation and slide them into of the chassis slowly. |
Before you begin
![]() Caution | Make sure that all pairs of compute nodes and PCIe nodes are completely powered off before inserting XFMs. |
Procedure
Step1 | Swing the ejector handles to the open position. | ||
Step2 | Placing one hand underneath the module, align the module with the empty module slot on the rear of the chassis. ![]() | ||
Step3 | Holding the module level, slowly slide it almost all the way into the chassis until you feel some resistance. This resistance is normal. It occurs when the connectors at the rear of the module contact the socket inside the chassis.
| ||
Step4 | Grasp each of the ejector handles, and keeping them level, arc them inward toward the chassis. This step seats the module connectors into the sockets on the midplane.
| ||
Step5 | Push the ejector handles until both are parallel with the face of the module. |
Installing and Removing the UCS X-Fabric Module Blank
The UCS X-Fabric Module Blank (UCSX-9508-RBLK) is a filler module for the expansion slots on the bottom of the chassis rear. For more information, see Cisco UCS X-Fabric Module Blanks.
Use the following procedures to replace the UCSX-9508-RBLK.
-
Installing a UCS X-Fabric Module Blank
-
Removing a UCS X-Fabric Module Blank
Installing a UCS X-Fabric Module Blank
Use this procedure to install an UCS X-Fabric Module Blank in the bottom two slots in the chassis rear. These module blanks must be deployed in pairs and must be installed. You cannot operate the server chassis with empty IOM bays.
Procedure
Step1 | Placing one hand underneath the blank, align it with the empty slot at the bottom of the rear of the chassis. | ||
Step2 | Holding the blank level, slowly slide it all the way into the chassis until the blank stops.
| ||
Step3 | Grasp each of the module handles, and keeping them level, arc them inward toward the chassis. This step seats the blank connectors into the sockets on the midplane.
| ||
Step4 | Push the module handles until both are parallel with the face of the blank. The fan modules on the blank will power up when the module is completely seated. |
Removing a UCS X-Fabric Module Blank
Use this task to remove a UCS X-Fabric Module Blank (UCSX-9508-BLK).
Procedure
Step1 | Using your fingers, pinch the interior end of both handles to disengage the retention clip. This step unlocks the module handles so that they can move. | ||
Step2 | Keeping the modules handles level, pull them towards you so that they arc away from the chassis.
| ||
Step3 | Slowly slide the blank about halfway out of the chassis, then place your other hand underneath the blank to support it. | ||
Step4 | Continue sliding the blank out of the chassis until it is completely removed. | ||
Step5 | Reinsert a UCS X-Fabric Module blank (UCSX-9508-RBLK). |
What to do next
Installing a UCS X-Fabric Module Blank
Recycling Printed Circuit Boards
The Cisco UCS X9508 and some of its modules have printed circuit boards (PCBs) that must be disposed of in compliance with your appropriate recycling and e-waste regulations, including, but not limited to Commission Regulation (EU) 2019/424.
The following procedures are not standard field-service options. They should be used only by certified or approved recyclers.
-
Recycling the UCS 9108 25G IFM PCBs
-
Recycling the UCS 9108 100G IFM PCBs
-
Recycling the Chassis PCB Assembly (PCBA)
Recycling the Chassis PCB Assembly (PCBA)
Each Cisco UCS X9508 chassis has a PCBA (motherboard) that is connected to the chassis midplane sheet metal. You must disconnect the PCBA from the chassis sheet metal to recycle the PCBA. Each PCBA is attached to the midplane sheet metal by 19 M4 screws. You will need to disassemble and remove additional parts to gain access to the PCBA.
You will need to recycle the PCBA for each UCS X9508 chassis.
Use the following procedure to recycle the Cisco UCS X9508 motherboard.
Before you begin
![]() Note | |
To remove the chassis printed circuit board assembly (PCBA), the following requirements must be met:
-
The chassis must be disconnected from facility power.
-
The chassis must have all compute nodes and IFMs removed. If they are not removed, remove them now. Go to:
-
Removing a Compute Node
-
Removing an Intelligent Fabric Module
-
-
The chassis must be removed from the equipment rack.
You will find it helpful to gather a T10, T15, and T20 screwdriver before beginning this procedure.
Procedure
Step1 | At the rear of the chassis, remove the fan modules. See Removing a Fan Module. |
Step2 | On the left side of the chassis, use a T10 screwdriver to remove 14 M4 screws. ![]() |
Step3 | On the right side of the chassis, use a T10 screwdriver to remove 14 M4 screws plus the two captive M3 screws for the PEMs. ![]() |
Step4 | On the top of the chassis, use a T10 screwdriver to remove the eight M4 screws. ![]() |
Step5 | Remove the PEMs.
|
Step6 | Disconnect the rear bracket assembly:
|
Step7 | Grasp the rear bracket assembly and disconnect it from the rest of the chassis. |
Step8 | With the rear bracket assembly removed, disconnect the PCB:
|
Step9 | Recycle the sheet metal and motherboard in compliance with your local recycling and e-waste regulations. |
Recycling the UCS 9108 25G IFM PCBs
Each Cisco UCS Intelligent Fabric Module (IFM) has a printed circuit board (PCB) that is connected to the IFM's sheet metal tray. You must:
-
Disassemble and remove additional parts to gain access to the PCB.
-
Disconnect the PCB from the sheet metal to recycle the PCB.
-
Recycle each IFM in the Cisco UCS X9508 chassis.
Use the following procedure to recycle the UCS IFMs.
Before you begin
![]() Note | |
You will find it helpful to gather the following tools before beginning this procedure:
-
Screwdrivers: One each of T8 and T10 screwdriver, and #1 Phillips.
-
Nut drivers: One 8mm hexagonal.
Procedure
Step1 | Remove the following components by hand:
| ||||
Step2 | Remove the stiffener bracket.
| ||||
Step3 | Remove the horizontal rear bracket.
| ||||
Step4 | Disconnect additional components and fasteners.
| ||||
Step5 | Disconnect the remaining components from the PCBA.
| ||||
Step6 | Recycle the sheet metal and motherboard in compliance with your local recycling and e-waste regulations. |
What to do next
To remove the chassis motherboard, go to Recycling the Chassis PCB Assembly (PCBA).
Recycling the UCS 9108 100G IFM PCBs
Each Cisco UCS Intelligent Fabric Module (IFM) has a printed circuit board (PCB) that is connected to the IFM's sheet metal tray. You must:
-
Disassemble and remove additional parts to gain access to the PCB.
-
Disconnect the PCB from the sheet metal to recycle the PCB.
-
Recycle each IFM in the Cisco UCS X9508 chassis.
Use the following procedure to recycle the UCS IFMs.
Before you begin
![]() Note | |
You will find it helpful to gather the following tools before beginning this procedure:
-
Screwdrivers: One each of T8 and T10 screwdriver, and #1 Phillips.
-
Nut drivers: One 8mm hexagonal.
Procedure
Step1 | Remove the following components by hand:
![]() | ||||
Step2 | Remove the stiffener bracket.
| ||||
Step3 | Remove the horizontal rear bracket.
| ||||
Step4 | Disconnect additional components and fasteners.
| ||||
Step5 | Disconnect the remaining components from the PCBA.
| ||||
Step6 | Recycle the sheet metal and motherboard in compliance with your local recycling and e-waste regulations. |
What to do next
To remove the chassis motherboard, go to Recycling the Chassis PCB Assembly (PCBA).
Recycling X-Fabric Module PCBs
Each UCS X-Fabric Module has a printed circuit board (PCB) that is connected to module's sheet metal tray. To recycle each module's PCB, you must:
-
Disassemble and remove additional parts to gain access to the PCB.
-
Disconnect the PCB from the sheet metal to recycle the PCB.
-
Recycle each module in the Cisco UCS X9508 chassis.
Use the following task to recycle the X-Fabric modules.
Before you begin
![]() Note | |
You will find it helpful to gather the following tools before attempting this procedure:
-
Screwdrivers: One each of T8 and T10 screwdriver
-
Nut drivers: One 8mm hexagonal head nut driver.
Procedure
Step1 | Remove the following components by hand:
| ||||
Step2 | Remove the rear fan bracket.
| ||||
Step3 | Remove the rear back-panel connector bracket.
| ||||
Step4 | Remove additional components and fasteners.
| ||||
Step5 | Disconnect the PCB from the sheetmetal. | ||||
Step6 | Recycle the sheet metal and motherboard in compliance with your local recycling and e-waste regulations. |
What to do next
Choose the appropriate option:
-
To recycle an X-Fabric Module Blank motherboard, go to: Recycling X-Fabric Module Blank PCBs.
-
To recycle a 100G UCS Intelligent Fabric Module motherboard, go to: Recycling the UCS 9108 100G IFM PCBs.
-
To recycle a 25G UCS Intelligent Fabric Module motherboard, go to: Recycling the UCS 9108 25G IFM PCBs.
-
To recycle the chassis motherboard, go to Recycling the Chassis PCB Assembly (PCBA).
Recycling X-Fabric Module Blank PCBs
Each UCS X-Fabric Module Blank (module blank) has a printed circuit board (PCB) that is connected to module blank's sheet metal tray. To recycle each module blank's PCB, you must:
-
Disassemble and remove additional parts to gain access to the PCB.
-
Disconnect the PCB from the sheet metal to recycle the PCB.
-
Recycle each module blank in the Cisco UCS X9508 chassis.
Use the following task to recycle the module blank.
Before you begin
![]() Note | |
You will find it helpful to gather a T10 screwdriver before attempting this procedure:
Procedure
Step1 | Remove the following components by hand:
|
Step2 | Grasp the fan module support bracket and remove it. |
Step3 | Remove the vertical rear bracket.
|
Step4 | Remove additional components and fasteners.
|
Step5 | Recycle the sheet metal and motherboard in compliance with your local recycling and e-waste regulations. |
What to do next
Choose the appropriate option:
-
To recycle an X-Fabric Module motherboard, go to: Recycling X-Fabric Module PCBs.
-
To recycle a 100G UCS Intelligent Fabric Module motherboard, go to: Recycling the UCS 9108 100G IFM PCBs.
-
To recycle a 25G UCS Intelligent Fabric Module motherboard, go to: Recycling the UCS 9108 25G IFM PCBs.
-
To recycle the chassis motherboard, go to Recycling the Chassis PCB Assembly (PCBA).