Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (2024)

Table of Contents
Components Cisco UCS 9108 25G IFM Components Cisco UCS 9108 100G IFM Components Cisco UCS X9416 Fabric Module Components Cisco UCS X-Fabric Module Blank Components Installing and Removing a Compute Node Blank Removing a Compute Node Blank Installing a Compute Node Blank Installing and Removing a Compute Node Installing a Compute Node Removing a Compute Node Installing and Removing Power Supplies PSU Population Rules Installing a Power Supply Removing a Power Supply Replacing a PSU Blank Removing a PSU Blank Installing a PSU Blank Replacing the PSU Keying Bracket Removing the PSU Keying Bracket Installing the PSU Keying Bracket Replacing the Power Entry Modules (PEMs) Installing the Power Entry Modules Removing the Power Entry Modules Installing and Removing a Fan Module Fan Module Replacement Consideration Installing a Fan Module Removing a Fan Module Installing and Removing a Rear Module's Fan Installing a Fan for a UCS Intelligent Fabric Module (IFM) or X-Fabric Module (XFM) Blank Removing a Fan for a UCS Intelligent Fabric Module (IFM) or X-Fabric Module (XFM) Blank Installing and Removing an Intelligent Fabric Module Installing an Intelligent Fabric Module Removing an Intelligent Fabric Module Installing and Removing an X-Fabric Module Removing an X-Fabric Module Installing an X-Fabric Module Installing and Removing the UCS X-Fabric Module Blank Installing a UCS X-Fabric Module Blank Removing a UCS X-Fabric Module Blank Recycling Printed Circuit Boards Recycling the Chassis PCB Assembly (PCBA) Recycling the UCS 9108 25G IFM PCBs Recycling the UCS 9108 100G IFM PCBs Recycling X-Fabric Module PCBs Recycling X-Fabric Module Blank PCBs References

This chapter contains the following topics:

Components

The following figure shows an empty Cisco UCS X9508 server chassis and identifies the front, back, and vertical node slots, and horizontal module slots.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (1)

Note

Before you remove or install components, please ensure that all software applications are shut down and management software is in a good state.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (2)

Note

Whenever you remove a module from the chassis for an extended period of time, always replace the module with the appropriate blank panel. Failing to do so can result in heating and EMI issues. Blank panels can be ordered from Cisco Systems.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (3)

The side of the chassis has no handles because the chassis is heavy, and not intended to be lifted unless you are using a scissor lift or another type of mechanical lift device to bear the weight of the chassis. The right side of the chassis has the PSU Keying Bracket which enforces proper PSU orientation as well as proper PSU type.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (4)

The left side of the chassis has no handles.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (5)

1

Node slots (8).

Each slot is numbered horizontally below each slot.

Compute nodes and PCIe nodes can be inserted vertically and connect to the power socket for each slot.

2

PSU bays (6).

Each PSU bay is numbered vertically to the right of the bay.

Each PSU bay is keyed so that the PSU inserts only one way.

The front of the chassis accepts up to 8 Cisco UCS X210c M6 compute nodes with connections for power and basic signaling through the per-slot socket connections to the midplane. The front of the server chassis also hosts up to 6 PSUs providing power to the chassis power plane through internal connectors. PSUs are numbered one through six with PSU bay one as the topmost slot and PSU bay 6 on the bottom.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (6)

Caution

Any node slot that is not occupied must have a compute node blank panel (UCSX-9508-FSBK) installed.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (7)

1

Power Entry Modules (2)

Each PEM houses three IEC 320 compatible C20 power inlets inlet facility power.

2

IFM slots (2)

3

Fan Bays (4)

Fans are numbered 1 through 4 with fan 1 as the leftmost.

4

Expansion Slots (2)

The top of the chassis rear contains up to two Intelligent Fabric Modules (IFMs). Power connections and minimal signaling are supported through the per-slot socket connections to the midplane. Three vertically stacked Power Entry Module (PEM) connectors are also supported, which correspond with PSUs one through three, with PSU one as the topmost connector.

The middle of the chassis rear houses up to four fan modules and power is supplied through one connector per fan module. Fans are numbered from one to four with Fan 1 being the leftmost fan, and Fan 4 being the right most.

The bottom of the chassis rear houses two active fan modules. Power connections and minimal signaling are supported through the per-slot socket connections to the midplane. Three vertically stacked PEM connectors are also supported, which correspond with PSUs four through six, with PSU four as the topmost connector.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (8)

Note

Before you install, operate, or service the system, see the Regulatory Compliance and Safety Information for Cisco UCS for important safety information.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (9)

Warning

IMPORTANT SAFETY INSTRUCTIONS



This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. Use the statement number provided at the end of each warning to locate its translation in the translated safety warnings that accompanied this device. 
Statement 1071

SAVE THESE INSTRUCTIONS

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (10)

Warning

This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security. 
Statement1017

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (11)

Warning

Only trained and qualified personnel must be allowed to install, replace, or service thisequipment. Statement1030

Cisco UCS 9108 25G IFM Components

The Cisco UCS 9108 25G Intelligent Fabric Module has the following board-level components.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (12)

1

Fans (UCSX-RSFAN=), three, which are numbered 1 through 3 starting with the left fan.

2

One M.2 mini storage module slot

3

SFP28 Optical Ports.

Ports are arranged in two groups of four physical ports.

Port number 1 is the left port in this group, and port number 4 is the right port in the group.

4

SFP28 Optical Ports.

Ports are arranged in two groups of four physical ports.

Port number 5 is the left port in this group, and port number 8 is the right port in the group.

5

IFM ejector handles, left and right

Cisco UCS 9108 100G IFM Components

The Cisco UCS 9108 Intelligent Fabric Module (UCS-I-9108-100G) has the following board-level components.
Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (13)

1

Fans, (UCSX-RSFAN=), three, which are numbered 1 through 3 starting with the left fan

2

One M.2 mini storage module slot

3

QSFP28 Optical Ports.

Ports are arranged in two groups of four physical ports. Ports are stacked in vertical pairs, with two ports in each vertical port stack.

Port number 1 is the top port of the left port pair in this group, and port number 3 is the top port of the right port pair in the group.

4

QSFP28 Optical Ports.

Ports are arranged in two groups of four physical ports. Ports are stacked in vertical pairs, with two ports in each vertical port stack.

Port number 5 is the top port in the left port pair of this group, and port number 7 is the top port in the right port pair of the group.

5

IFM ejector handles, left and right

Cisco UCS X9416 Fabric Module Components

The Cisco X9416 module (UCSX-F-9416) has the following components.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (14)

1

Fans (UCSX-RSFAN=), three, which are numbered 1 through 3 starting with the left fan

2

Module Ejector Handles, Left and Right

Cisco UCS X-Fabric Module Blank Components

The Cisco X-Fabric Module Blank (UCSX-9508-RBLK) has the following components.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (15)

1

Fans (UCSX-RSFAN=), three, which are numbered 1 through 3 starting with the left fan

2

Module Ejector Handles, Left and Right

Installing and Removing a Compute Node Blank

The UCS X9508 supports up to 8 compute nodes, with a minimum configuration of one compute node. If compute node slots do not contain a compute node, you must install a compute node blank.

Use these procedures to replace a compute node blank:

  • Installing a Compute Node Blank

  • Removing a Compute Node Blank

Removing a Compute Node Blank

Do not operate the server chassis with an empty compute node slot. Fill any empty compute node slots with either a blank (UCSX-9508-FSBK) or a compute node.

Use this task to remove a compute node blank.

Procedure

Step1

Grasp the compute node by the finger holds.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (16)

Step2

Pull the compute node blank towards you until it is completely removed from the chassis.

Notice that the module blank has indicators that show how to orient the blank. You will use this information when you install a blank.
Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (17)

What to do next

Choose the appropriate option:

  • Installing a Compute Node

  • Installing a Compute Node Blank

Installing a Compute Node Blank

If you remove a compute node, and you will not be installing another compute node, you must install a compute node blank. Do not operate the server with an empty compute node slot. The minimum configuration is 1 installed compute node, so in this configuration you need 7 module blanks installed.

Compute node blanks are interchangeable within the same chassis or other chassis.

Use this task to install a compute node blank

Procedure

Step1

Grasp the blank by the finger holds.

Step2

Hold the module blank vertically and align the module blank with the slot.

Note

The module blank has an arrow and the word UP that show how to orient the blank. Also, if you attempt to install the blank with the wrong orientation, the module does not sit flush with the front of the chassis.

. Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (18)

Step3

Keeping the compute node blank vertical, slide it into the slot until the blank is flush with the face of the chassis.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (19)

Installing and Removing a Compute Node

The Cisco UCS X9508 server chassis supports full-height compute nodes. For details, see the Installation and Service Note for your compute nodes. See http://www.cisco.com/en/US/products/ps10280/prod_installation_guides_list.html

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (20)

Caution

When working with the compute nodes, handle them carefully to avoid damage to the modules, connectors, and pins.

Installing a Compute Node

Use this task to install a compute node in an empty slot.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (21)

Caution

When working with the compute nodes, handle them carefully to avoid damage to the modules, connectors, and pins! Make sure that the modules are level during insertion and slide them into the chassis slowly.

Before you begin

If there is a module blank in the slot where you want to install a compute node, remove the blank now. See Removing a Compute Node Blank.

Compute nodes are shipped with the ejector handles closed and locked. Each compute node has a release button in the center of the node that releases the ejectors from the locked position.

Procedure

Step1

Press the release button at the center of the compute node faceplate to release the ejectors.

Caution

The ejectors have a hook at the pivoting end that attaches to the compute node. While you are inserting the compute node, keep the ejectors open as shown in the following illustration. If the ejectors are not open, the hook can be an obstruction while sliding the node into the chassis.

Step2

Holding the compute node vertical, align it with the empty module bay in the chassis.

The compute node is correctly aligned when the server top cover is pointing to the left.
Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (22)

Step3

Keeping the compute node vertical, slowly slide it into the chassis.

As the compute node is almost completely installed, you might feel some resistance. This resistance is normal. It occurs because the connectors at the rear of the compute node contacts the connector on the inside of the chassis.

Caution

Make sure to apply even pressure when sliding the module into the chassis. Do not push down or pull up on the module handles, and do not apply more force to one ejector handle than the other.

Step4

When the compute node is almost completely installed, grasp the ejector handles and arc them toward each other.

This step seats the compute node into the connector. The compute node should power up.

Caution

Make sure to apply even pressure when closing the module ejector handles! Do not push down or pull up on the module handles, and do not apply more force to one ejector handle than the other.

Step5

Push the ejectors until they are parallel with the face of the compute node.

When the compute node is completely installed, the retention latches at the end of each handle click into place.

Removing a Compute Node

Use this task to remove a compute node.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (23)

Caution

When working with the compute nodes, handle them carefully to avoid damage to the modules, connectors, and pins! Make sure that the modules are level during removal and slide them out of the chassis slowly.

Before you begin

Do not operate the server with an empty compute node slot. If you will not be installing a compute node in an empty slot, install a compute node blank to cover the empty slot.

Procedure

Step1

Press the release button at the center of the compute node faceplate to disengage the ejector handles.

Step2

Grasp the ejector handles and pull them outward so that they arc vertically away from each other.

While moving the compute node handles, you might feel some resistance. This resistance is normal. It occurs because the connectors at the rear of the compute node are unseating from the corresponding sockets in the chassis.

Also, when the compute node disconnects from the midplane, the server powers off.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (24)

Step3

Grasp the compute node handles and slide the compute node partially out of the chassis.

Make sure to keep the compute node vertical while removing it.

Caution

Make sure to apply even pressure when sliding the module out of the chassis. Do not push down or pull up on the module handles, and do not apply more force to one ejector handle than the other.

Step4

Place your other hand underneath the compute node to support it and slide the compute node completely out of the chassis.

What to do next

Fill the empty compute node slot. Go to the appropriate option:

  • Installing a Compute Node

  • Installing a Compute Node Blank

Installing and Removing Power Supplies

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (25)

Note

The power supplies are keyed to work only with their respective power expansion module (PEM), depending on the chassis version.

When in installing and removing power supplies, make sure that the minimum number of power supplies are active before replacing the other PSUs. For example, in a 3+3 grid power configuration, at least 3 PSUs must be active before replacing the other 3 units one at a time per grid.

The PSUs are installed vertically along the side of the chassis.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (26)

PSU Population Rules

When you install PSUs, they must be equally divided into top and bottom PSU slots to ensure redundancy. See the following PSU population rules.

  • For 2 PSUs: Install a PSU in slots 1 and 4. This is the minimum supported config.

  • For 3 PSUs: Install a PSU in slots 1, 2, and 4.

  • For 4 PSUs: Install a PSU in slots 1, 2, 4, and 5.

  • For 5 PSUs: Install a PSU in slots 1, 2, 3, 4, and 5.

  • For 6 PSUs: Install a PSU in all slots.

Any slots that do not contain a PSU must be covered by a PSU blank.

Installing a Power Supply

The Cisco UCS X9508 AC PSU does not have a discrete power switch. It powers on immediately when it is successfully connected to the power midplane. When installing a PSU, you must comply with the PSU population rules. See PSU Population Rules.

PSUs are hot swappable with a minimum population of two in the chassis to provide redundancy. PSUs are interchangeable and none are reserved through the management software.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (27)

Caution

When connecting the chassis to facility power, make sure not to overload the capacity of a PDU or power strip. For example, do not connect all PSUs to one PDU or power strip that is not capable of carrying the total power draw of the chassis.

Use the following procedure to install the PSUs.

Procedure

Step1

Grasp the PSU with one hand.

Step2

Use your other hand to support the PSU, and holding it level, orient it with the PSU bay.

The PSU is correctly oriented when the latch is facing you and parallel with the right side of the PSU bay.

Step3

Holding the PSU level, slide it into the PSU bay.

Note

When the PSU is almost all the way in, you will feel some resistance, which is normal. The resistance is the connector at the rear of the PSU meeting the power socket inside the chassis.

The PSU will power on when you have successfully seated it in its socket.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (28)

Step4

For each PSU that must be installed, repeat these steps.

Step5

Verify the power supplies are operating by checking the power supply LEDs. See LED Locations and Interpreting LEDs.

Note

Both grids in a power redundant system should have the same number of power supplies. If your system is configured for grid power (N+N redundancy), slots 1, 2 and 3 are assigned to grid 1, and slots 4, 5, and 6 are assigned to grid 2. If fewer than six power supplies (PS) are configured in grid redundant mode, they should be equally distributed between the grid 1 and grid 2 slots.

Removing a Power Supply

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (29)

Caution

If you are using the Cisco UCS X9508 server chassis with one power supply, which is a non-redundant power configuration. Removing the power supply will cause the compute nodes and chassis to shut down. If you are using more than two power supplies, and you remove one of them (the minimum supported power configuration is 3 PSUs), the servers continue to operate as long as the other power supplies are sufficient to meet the power requirements of the number of compute nodes in the chassis.

The PSU has a locking latch that secures the PSU in the chassis. You must unlock the latch to remove the PSU. You can expect some resistance as the PSU slides out due to its weight.

Procedure

Step1

Place your thumb on the PSU locking latch at the vertical fingerhold on the right side of the blank's faceplate and allow your other fingers to rest along the side of the chassis.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (30)

Step2

Press the latch to unlock the PSU, then pull until it disengages from the power socket inside the chassis.

You will feel some resistance initially as the connector at the rear of the PSU unseats from the power socket inside the chassis.

Step3

As you slide the PSU out of the chassis, use your other hand to support the PSU.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (31)

Step4

Install a blank power supply filler panel if the power supply bay is to remain empty.

What to do next

Choose the appropriate option:
  • If you will be reinstalling a PSU, go to Installing a Power Supply

  • If you will be installing a PSU blank, go to Installing a PSU Blank.

Replacing a PSU Blank

PSU blanks (UCSX-9508-PSUBK) are interchangeable, but if you will be operating the server chassis without a PSU, the empty bay must be covered with a PSU blank. Replace a PSU blank when you remove a PSU but will not install another PSU in that PSU bay, or when you remove a PSU blank and need to cover the empty PSU bay.

  • Removing a PSU Blank

  • Installing a PSU Blank

Removing a PSU Blank

Use this procedure to remove a PSU blank.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (32)

Note

The PSU blank is a small plastic piece. It does not have a locking latch, so it slides out easily.

Procedure

Step1

Place your thumb behind the vertical fingerhold on the right side of the blank's faceplate and allow your other fingers to rest along the side of the chassis.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (33)

Step2

Using your thumb, grasp the PSU blank by the vertical fingerhold and pull the PSU blank straight towards you.

The PSU should easily slide out of the chassis.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (34)

What to do next

Choose the appropriate option:

  • If you are installing a PSU, go to Installing a Power Supply.

  • If you are installing a PSU blank, go to Installing a PSU Blank.

Installing a PSU Blank

The minimum supported power configuration for the UCS X9508 server chassis is three PSUs. If you will be operating the server chassis with an empty PSU bay, it must be covered with a PSU blank (UCSX-9508-PSUBK).

Use this procedure to install a PSU blank.

Procedure

Step1

Grasp the PSU blank by the vertical finger hold on the right side of the blank's face.

Step2

Align the PSU blank so that the word UP is facing up, and the handle is parallel to the right side of the PSU bay.

Step3

Insert the PSU blank until its faceplate is flush with the front of the server chassis.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (35)

Replacing the PSU Keying Bracket

The PSU Keying bracket is attached to the right exterior side of the chassis. The bracket ensures that only the correct type of PSU can be installed, and that the PSU is inserted in correct orientation in the chassis.

Use the following procedures to replace the PSU Keying bracket:

  • Removing the PSU Keying Bracket

  • Installing the PSU Keying Bracket

Removing the PSU Keying Bracket

Use this procedure to remove the PSU Keying bracket.

Before you begin

The chassis must be completely removed from the rack to provide access to the exterior of the chassis where the PSU Keying bracket will be installed.

When the chassis is removed from the rack, make sure that you place the chassis on an ESD-safe workspace, for example, a rubberized mat.

Procedure

Step1

If you have not already removed the chassis from the rack, do so now.

Go to Removing the Chassis from a Rack.

Caution

Make sure to follow all safety requirements while uninstalling the chassis, including using a device, such as a mechanical lift, to bear the weight of the chassis.

Step2

With the chassis in an ESD-safe work area, locate the PSU Keying bracket on the right exterior side of the chassis.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (36)

Step3

Using a T10 screwdriver, remove the six screws that attach the bracket to the chassis.

Step4

Grasp the PSU keying bracket and detach it from the chassis.

Step5

Keep the screws and bracket.

What to do next

Installing the PSU Keying Bracket.

Installing the PSU Keying Bracket

Use this task to install a PSU Keying bracket (UCSX-9508-KEY-AC=).

Procedure

Step1

With the chassis on an ESD-safe work area, grasp the new PSU Keying Bracket, and align it with right exterior side of the chassis.

Step2

Place the bracket against the side of the chassis, aligning the screwholes in the bracket with the screwholes in the chassis.

Step3

Insert the 6 screws into the screwholes.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (37)

Step4

Using a T10 screwdriver, secure the bracket to the chassis by tightening each screw to snug.

If you have access to a torque wrench, tighten the screws to 6 in-lb.

Step5

Reinstall the chassis:

  1. Insert the chassis into the rack.

  2. Reinstall the chassis components and reconnect any cables that were disconnected.

    For additional info, see Installing the Chassis.

Replacing the Power Entry Modules (PEMs)

The Cisco UCS X9508 chassis contains two power entry modules (PEMs). Each PEM is a grouping of 3 IEC 320 compatible C20 power inlets. One PEM supports PSUs 1 through 3, and one PEM supports PSUs 4 through 6. Each PEM is field replaceable.

Use the following procedures to replace the PEMs:

  • Installing the Power Entry Modules

  • Removing the Power Entry Modules

Installing the Power Entry Modules

Use this procedure to install a PEM.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (38)

Note

The following task shows installing both PEMs. If you are installing only one PEM, you will need to tighten only the PEM screw for the replaced PEM, not both screws as shown in the illustrations.

Before you begin

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (39)

DANGER

Follow all electrical safety precautions when working with facility power. Failure to do so can result in damage to the equipment or pose a risk of injury or death to personnel.

Procedure

Step1

Grasp the PEM and orient it correctly.

The PEM is keyed so that you can insert it only one way.

Step2

Holding the PEM level, slide it into the PEM slot.

You might feel some resistance as the connector on the rear of the PEM meets the connector on the interior of the chassis.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (40)

Step3

Using a T10 screwdriver, tighten the captive screws which are easily identifiable because they are next to the electrical ground icons on the chassis walls.

  1. Tighten the exterior captive screws.

    Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (41)

  2. Tighten the interior captive screws.

    Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (42)

Step4

Reinstall the IFMs and expansion modules.

  1. Go to Installing an Intelligent Fabric Module.

  2. Go to Installing a UCS X-Fabric Module Blank.

Step5

Reconnect all power cables.

The chassis automatically powers on when it receives inlet power.

Removing the Power Entry Modules

PEMs support inlet power to the chassis from the facility. It is a best practice to remove all power from the system when replacing a PEM.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (43)

DANGER

Follow all electrical safety precautions when working with facility power. Failure to do so can result in damage to equipment or pose a risk of injury or death to personnel.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (44)

Note

The following task shows removing both PEMs. If you are removing only one PEM, you will need to loosen only the PEM screw for the replaced PEM, not both screws as shown in the illustrations.

Before you begin

The power entry modules (PEMs) are connected to facility power, so you must disconnect facility power from the PEM that you will be removing.

Procedure

Step1

Power down all compute nodes.

Step2

Remove any power cables that are attached to the PEM.

Step3

Remove the IFMs and expansion modules.

  1. Go to Removing an Intelligent Fabric Module.

  2. Go to Removing a UCS X-Fabric Module Blank.

Step4

Using a T10 screwdriver, loosen the captive screws that attach the PEM to the chassis.

The captive screws are easily identifiable because they are next to the electrical ground icons on the chassis walls.

  1. Loosen the exterior captive screws.

    Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (45)

  2. Loosen the interior captive screws.

    Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (46)

Step5

Grasp the PEM and slide it out of the chassis.

When you remove a PEM, you must replace it with another one. Do not operate the system with an empty PEM slot.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (47)

What to do next

Install a PEM. Go to Installing the Power Entry Modules.

Installing and Removing a Fan Module

You can hot swap a fan module (UCSX-9508-FAN) without causing an electrical hazard or damage to the system. However, you can only remove one fan module while the system is operating. Removing more than one fan module could cause overheating.

Fan Module Replacement Consideration

While a fan module is absent from the chassis, the pair of compute nodes physically associated with that fan may be throttled to prevent thermal overload. After the fan module is replaced in the chassis, throttling is removed and the associated blades resume normal operation.

To minimize the impact to system performance, do not remove a fan module until a replacement fan module is available. Leaving the fan module out of the chassis for longer durations of time will result in extreme power throttling of the associated compute nodes, but the nodes will not shutdown.

The following table shows the mapping of fan modules to their associated compute nodes.

Fan Module

Compute Node Slots

1

7, 8

2

5, 6

3

3, 4

4

1, 2

Installing a Fan Module

Procedure

Step1

Hold the fan module with the handle at the bottom and place your other hand underneath the fan module to support it.

Step2

Align the fan with the fan bay in the rear of the chassis.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (48)

Step3

Slide the fan into the chassis until it is flush with the face of the chassis.

Note

Make sure that the latch on the handle is engaged with the chassis.

When the fan module is almost completely installed, you might feel some resistance. The resistance is normal, and it occurs when the connector at the rear of the fan contacts the corresponding socket inside the chassis.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (49)

Step4

Listen for the fan to power up and verify that the LED behavior is as expected.

See LED Locations and Interpreting LEDs.

Removing a Fan Module

Procedure

Step1

Grasp the fan module handle and push down on the release button.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (50)

Step2

Slide the fan module partially out of the chassis and place your hand underneath it to support it.

When the fan disconnects from the midplane, it will power down.

Step3

Slide the fan completely out of the chassis, making sure to support its weight with your other hand.

Caution

The fan module is relatively heavy! Do not attempt to handle or carry it by only its handle. Instead, make sure support the fan's weight with your other hand.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (51)

What to do next

Insert a fan module. Go to Installing a Fan Module.

Installing and Removing a Rear Module's Fan

The Cisco UCS X9508 Intelligent Fabric Module (IFM) and X-Fabric Module (XFM) blanks use the same fan (UCSX-RSFAN=), which makes the fans interchangeable between these modules and module blanks. In a typical configuration, there are three fans numbered from one to three.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (52)

Note

The fans for IFM and XFMs (UCSX-RSFAN=) are different from the fan modules (UCSX-9508-FAN) that provide cooling and ventilation for the entire server chassis. These two types of fans are not interchangeable.

Use the following procedures to replace a fan on a Cisco UCS X9508 module or module blank.

  • Installing a Fan for a UCS Intelligent Fabric Module (IFM) or X-Fabric Module (XFM) Blank

  • Removing a Fan for a UCS Intelligent Fabric Module (IFM) or X-Fabric Module (XFM) Blank

Installing a Fan for a UCS Intelligent Fabric Module (IFM) or X-Fabric Module (XFM) Blank

Use this task to install the fan (UCSX-RSFAN=) for a UCS Intelligent Fabric Module (IFM) or X-Fabric Module (XFM) Blank.

Procedure

Step1

Align the fan correctly.

  1. Align the power connector on the replacement fan with power connector on the board.

  2. Align the guides on long fan side walls with the corresponding cutouts on the module.

    Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (53)

Step2

Press down evenly on the fan until it is fully seated.

Make sure the fan is level while you're installing it. You will feel the fan click into place when it is correctly seated on the module or module blank.

Removing a Fan for a UCS Intelligent Fabric Module (IFM) or X-Fabric Module (XFM) Blank

Use the following procedure for removing a fan (USCX-RSFAN=) from a UCS Intelligent Fabric Module (IFM) or X-Fabric Module (XFM) Blank.

Procedure

Step1

Grasp the fan by the tabs on each long side wall.

Step2

Pull the fan straight up.

This step disconnects the fan from the power connector and lifts the fan off of the board.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (54)

What to do next

Insert a fan module. Go to Installing a Fan for a UCS Intelligent Fabric Module (IFM) or X-Fabric Module (XFM) Blank.

Installing and Removing an Intelligent Fabric Module

Intelligent Fabric Modules (IFMs) install in the rear of the chassis. They are always deployed in pairs, and the minimum IFM configuration for each UCS X9508 is two. For more information, see Intelligent Fabric Modules.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (55)

Caution

When working with the IFMs, handle them carefully to avoid damage to the modules, connectors, and pins.

Use the following procedures to replace an IFM:

  • Installing an Intelligent Fabric Module

  • Removing an Intelligent Fabric Module

Installing an Intelligent Fabric Module

Intelligent Fabric Modules (IFM) must be deployed in pairs, so there are no IFM module blanks that can be installed.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (56)

Caution

When working with the IFMs, handle them carefully to avoid damage to the modules, connectors, and pins! Make sure that the modules are level during insertion and slide them into the chassis slowly.

Procedure

Step1

If the IFM has a cable management tray, remove it.

See Removing the Cable Management Tray.

Step2

Swing the ejector handles to the open position.

Step3

Placing one hand underneath the IFM, align the module with the empty IFM slot on the rear of the chassis.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (57)

Step4

Holding the IFM level, slide it almost all the way into the chassis until you feel some resistance.

This resistance is normal. It occurs when the connectors at the rear of the IFM contact the socket inside the chassis.

Caution

Make sure to apply even pressure when sliding the module into the chassis. Do not push down or pull up on the module handles, and do not apply more force to one ejector handle than the other.

Step5

Grasp each of the ejector handles, and keeping them level, slowly arc them inward toward the chassis.

This step seats the IFM connectors into the sockets on the midplane.

Caution

Make sure to apply even pressure when closing the module ejector handles! Do not push down or pull up on the module handles, and do not apply more force to one ejector handle than the other.

Step6

Push the ejector handles until both are parallel with the face of the IFM.

Make sure the ejector latch is fully inserted in the front panel

Step7

If the IFM has a cable management tray, attach it.

See Installing the Cable Management Tray.

Removing an Intelligent Fabric Module

Intelligent Fabric Modules (IFM) must be deployed in pairs, so when you remove one, you must insert another IFM in its place.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (58)

Caution

When working with the IFMs, handle them carefully to avoid damage to the modules, connectors, and pins! Make sure that the modules are level during removal and slide them out of the chassis slowly.

Procedure

Step1

If the IFM has a cable management tray, remove it.

See Removing the Cable Management Tray.

Step2

Using your fingers, pinch the interior end of both handles to disengage the ejector latch.

This step unlocks the module handles so that they can move.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (59)

Step3

Keeping the modules handles level, pull them towards you so that they arc away from the chassis.

You might feel some resistance as the IFM disconnects from the socket inside the chassis.

Step4

Slide the module about halfway out of the chassis, then place your other hand underneath the IFM to support it.

Caution

Make sure to apply even pressure when sliding the module out of the chassis. Do not push down or pull up on the module handles, and do not apply more force to one ejector handle than the other.

Step5

Continue sliding the IFM out of the chassis until it is completely removed.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (60)

What to do next

Insert an IFM. Go to Installing an Intelligent Fabric Module

Installing and Removing an X-Fabric Module

X-Fabric Modules, such as the Cisco UCS X9416, are required when the UCS X9508 chassis contains one or more pairs of X-Series compute nodes and X-Series PCIe Nodes, such as the Cisco UCS X440p PCIe node. For more information, see X-Fabric Modules.

For information about the Cisco UCS X440p PCIe Node, go to the Cisco UCS X440p PCIe Node Hardware Installation and Service Guide.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (61)

Caution

Because both XFMs connect to all slots on the front of the server chassis, all pairs of compute nodes and PCIe nodes must be powered off before removing or inserting XFMs.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (62)

Caution

Although the Cisco UCS X-Fabric Modules can be removed, it is a best practice to leave them installed even during chassis installation.

Use the following procedures to install or remove an X-Fabric Module.

  • Removing an X-Fabric Module

  • Installing an X-Fabric Module

Removing an X-Fabric Module

Use the following procedure to remove a Cisco UCS X-Fabric Module.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (63)

Caution

When working with the XFMs, handle them carefully to avoid damage to the modules, connectors, and pins! Make sure that the modules are level during removal and slide them out of the chassis slowly.

Before you begin

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (64)

Caution

Make sure that all pairs of compute nodes and PCIe nodes are completely powered off before removing an X-Fabric Modle (XFM).

Procedure

Step1

Using your fingers, pinch the interior end of both handles to disengage the ejector latch.

This step unlocks the module handles so that they can move.

Step2

Keeping the modules handles level, pull them towards you so that they arc away from the chassis.

Caution

Make sure to apply even pressure when sliding the module out of the chassis. Do not push down or pull up on the module handles, and do not apply more force to one ejector handle than the other.

You might feel some resistance as the module disconnects from the socket inside the chassis.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (65)

Step3

Keeping the module level, slowly slide the module about halfway out of the chassis, then place your other hand underneath the module to support it.

Step4

Continue sliding the module out of the chassis until it is completely removed.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (66)

What to do next

Insert an X-Fabric Module. Go to Installing an X-Fabric Module

Installing an X-Fabric Module

Use the following procedure to install a Cisco UCS X-Fabric Module.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (67)

Caution

When working with the XFMs, handle them carefully to avoid damage to the modules, connectors, and pins! Make sure that the modules are level during installation and slide them into of the chassis slowly.

Before you begin

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (68)

Caution

Make sure that all pairs of compute nodes and PCIe nodes are completely powered off before inserting XFMs.

Procedure

Step1

Swing the ejector handles to the open position.

Step2

Placing one hand underneath the module, align the module with the empty module slot on the rear of the chassis.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (69)

Step3

Holding the module level, slowly slide it almost all the way into the chassis until you feel some resistance.

This resistance is normal. It occurs when the connectors at the rear of the module contact the socket inside the chassis.

Caution

Make sure to apply even pressure when sliding the module into the chassis. Do not push down or pull up on the module handles, and do not apply more force to one ejector handle than the other.

Step4

Grasp each of the ejector handles, and keeping them level, arc them inward toward the chassis.

This step seats the module connectors into the sockets on the midplane.

Caution

Make sure to apply even pressure when closing the module ejector handles! Do not push down or pull up on the module handles, and do not apply more force to one ejector handle than the other.

Step5

Push the ejector handles until both are parallel with the face of the module.

Make sure the ejector latch is fully inserted in the front panel

Installing and Removing the UCS X-Fabric Module Blank

The UCS X-Fabric Module Blank (UCSX-9508-RBLK) is a filler module for the expansion slots on the bottom of the chassis rear. For more information, see Cisco UCS X-Fabric Module Blanks.

Use the following procedures to replace the UCSX-9508-RBLK.

  • Installing a UCS X-Fabric Module Blank

  • Removing a UCS X-Fabric Module Blank

Installing a UCS X-Fabric Module Blank

Use this procedure to install an UCS X-Fabric Module Blank in the bottom two slots in the chassis rear. These module blanks must be deployed in pairs and must be installed. You cannot operate the server chassis with empty IOM bays.

Procedure

Step1

Placing one hand underneath the blank, align it with the empty slot at the bottom of the rear of the chassis.

Step2

Holding the blank level, slowly slide it all the way into the chassis until the blank stops.

Caution

Make sure to apply even pressure when sliding the module into the chassis. Do not push down or pull up on the module handles, and do not apply more force to one ejector handle than the other.

Step3

Grasp each of the module handles, and keeping them level, arc them inward toward the chassis.

This step seats the blank connectors into the sockets on the midplane.

Caution

Make sure to apply even pressure when closing the module ejector handles! Do not push down or pull up on the module handles, and do not apply more force to one ejector handle than the other.

Step4

Push the module handles until both are parallel with the face of the blank.

The fan modules on the blank will power up when the module is completely seated.

Removing a UCS X-Fabric Module Blank

Use this task to remove a UCS X-Fabric Module Blank (UCSX-9508-BLK).

Procedure

Step1

Using your fingers, pinch the interior end of both handles to disengage the retention clip.

This step unlocks the module handles so that they can move.

Step2

Keeping the modules handles level, pull them towards you so that they arc away from the chassis.

Caution

Make sure to apply even pressure when sliding the blank out of the chassis. Do not push down or pull up on the module handles, and do not apply more force to one ejector handle than the other.

Step3

Slowly slide the blank about halfway out of the chassis, then place your other hand underneath the blank to support it.

Step4

Continue sliding the blank out of the chassis until it is completely removed.

Step5

Reinsert a UCS X-Fabric Module blank (UCSX-9508-RBLK).

What to do next

Installing a UCS X-Fabric Module Blank

Recycling Printed Circuit Boards

The Cisco UCS X9508 and some of its modules have printed circuit boards (PCBs) that must be disposed of in compliance with your appropriate recycling and e-waste regulations, including, but not limited to Commission Regulation (EU) 2019/424.

The following procedures are not standard field-service options. They should be used only by certified or approved recyclers.

  • Recycling the UCS 9108 25G IFM PCBs

  • Recycling the UCS 9108 100G IFM PCBs

  • Recycling the Chassis PCB Assembly (PCBA)

Recycling the Chassis PCB Assembly (PCBA)

Each Cisco UCS X9508 chassis has a PCBA (motherboard) that is connected to the chassis midplane sheet metal. You must disconnect the PCBA from the chassis sheet metal to recycle the PCBA. Each PCBA is attached to the midplane sheet metal by 19 M4 screws. You will need to disassemble and remove additional parts to gain access to the PCBA.

You will need to recycle the PCBA for each UCS X9508 chassis.

Use the following procedure to recycle the Cisco UCS X9508 motherboard.

Before you begin

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (70)

Note

For Recyclers Only! This procedure is not a standard field-service option. This procedure is for recyclers who will be reclaiming the electronics and sheet metal for proper disposal to comply with local eco design and e-waste regulations.

To remove the chassis printed circuit board assembly (PCBA), the following requirements must be met:

  • The chassis must be disconnected from facility power.

  • The chassis must have all compute nodes and IFMs removed. If they are not removed, remove them now. Go to:

    • Removing a Compute Node

    • Removing an Intelligent Fabric Module

  • The chassis must be removed from the equipment rack.

You will find it helpful to gather a T10, T15, and T20 screwdriver before beginning this procedure.

Procedure

Step1

At the rear of the chassis, remove the fan modules.

See Removing a Fan Module.

Step2

On the left side of the chassis, use a T10 screwdriver to remove 14 M4 screws.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (71)

Step3

On the right side of the chassis, use a T10 screwdriver to remove 14 M4 screws plus the two captive M3 screws for the PEMs.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (72)

Step4

On the top of the chassis, use a T10 screwdriver to remove the eight M4 screws.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (73)

Step5

Remove the PEMs.

  1. On the interior of the chassis, use the T10 screwdriver to remove the two M3 captive screws for the PEMs, which are indicated by the ground symbol (Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (74)).

  2. When the screws are removed, grasp each PEM and remove it from the chassis.

    Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (75)

Step6

Disconnect the rear bracket assembly:

  1. Grasp the two cables and unplug them.

  2. Using a T20 screwdriver, remove the four M4 screws.

    Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (76)

Step7

Grasp the rear bracket assembly and disconnect it from the rest of the chassis.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (77)

Step8

With the rear bracket assembly removed, disconnect the PCB:

  1. Grasp the cable and unplug it.

  2. Using the T15 screwdriver, remove the 19 M4 screws, and remove the PCB from the chassis midplane sheet metal.

    Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (78)

Step9

Recycle the sheet metal and motherboard in compliance with your local recycling and e-waste regulations.

Recycling the UCS 9108 25G IFM PCBs

Each Cisco UCS Intelligent Fabric Module (IFM) has a printed circuit board (PCB) that is connected to the IFM's sheet metal tray. You must:

  • Disassemble and remove additional parts to gain access to the PCB.

  • Disconnect the PCB from the sheet metal to recycle the PCB.

  • Recycle each IFM in the Cisco UCS X9508 chassis.

Use the following procedure to recycle the UCS IFMs.

Before you begin

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (79)

Note

For Recyclers Only! This procedure is not a standard field-service option. This procedure is for recyclers who will be reclaiming the electronics and sheet metal for proper disposal to comply with local eco design and e-waste regulations.

You will find it helpful to gather the following tools before beginning this procedure:

  • Screwdrivers: One each of T8 and T10 screwdriver, and #1 Phillips.

  • Nut drivers: One 8mm hexagonal.

Procedure

Step1

Remove the following components by hand:

  1. Grasp each fan module cable and remove it.

  2. Grasp each fan module and remove it.

  3. Grasp the M.2 storage module and remove it.

  4. Grasp the light pipe and remove it.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (80)

Step2

Remove the stiffener bracket.

  1. Using a T10 screwdriver, remove the M3 screws.

  2. Grasp the bracket and remove it.

    Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (81)

Step3

Remove the horizontal rear bracket.

  1. Using a T8 screwdriver, remove the M3 screws on the exterior of the IFM.

    Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (82)

  2. Using a T10 screwdriver, remove the M3 screws on the interior of the IFM.

  3. Grasp the bracket and remove it.

    Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (83)

Step4

Disconnect additional components and fasteners.

  1. Using a T8 screwdriver, remove the M3 screw on the IFM faceplate.

  2. Grasp the plastic HDMI plug and remove it.

    Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (84)

  3. Using an 8mm hexagonal nut driver, remove the standoffs.

  4. Using a T10 screwdriver, remove the M3 screws.

    Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (85)

    Red circles (Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (86) )

    M3 hexagonal standoffs, 4

    Blue circles (Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (87) )

    M3 screws, 6

  5. Grasp the PCBA and disconnect it from the sheet metal.

Step5

Disconnect the remaining components from the PCBA.

  1. Using the T10 screwdriver, remove the M3 screws for the top heatsink.

    Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (88)

  2. Turn the PCBA over so that the bottom is facing up.

  3. Using the #1 Phillips screwdriver and remove the M2 screws.

  4. Using a pliers, release the four heatsink pushpins.

    Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (89)

    Red circles (Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (90) )

    M2 screws for plastic bracket, 4

    Blue circles (Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (91) )

    Heatsink pushpins, 4

  5. Turn the PCBA over again so that the top is facing up.

  6. Grasp the plastic bracket for the M.2 module and remove it.

  7. If the top heat sink is still attached, grasp and remove it.

  8. Grasp the three fan baffles and remove them.

  9. Grasp the center heatsink and remove it.

    Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (92)

Step6

Recycle the sheet metal and motherboard in compliance with your local recycling and e-waste regulations.

What to do next

To remove the chassis motherboard, go to Recycling the Chassis PCB Assembly (PCBA).

Recycling the UCS 9108 100G IFM PCBs

Each Cisco UCS Intelligent Fabric Module (IFM) has a printed circuit board (PCB) that is connected to the IFM's sheet metal tray. You must:

  • Disassemble and remove additional parts to gain access to the PCB.

  • Disconnect the PCB from the sheet metal to recycle the PCB.

  • Recycle each IFM in the Cisco UCS X9508 chassis.

Use the following procedure to recycle the UCS IFMs.

Before you begin

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (93)

Note

For Recyclers Only! This procedure is not a standard field-service option. This procedure is for recyclers who will be reclaiming the electronics and sheet metal for proper disposal to comply with local eco design and e-waste regulations.

You will find it helpful to gather the following tools before beginning this procedure:

  • Screwdrivers: One each of T8 and T10 screwdriver, and #1 Phillips.

  • Nut drivers: One 8mm hexagonal.

Procedure

Step1

Remove the following components by hand:

  1. Grasp each fan module cable and remove it.

  2. Grasp each fan module and remove it.

  3. Grasp the M.2 storage module and remove it.

  4. Grasp the light pipe and remove it.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (94)

Step2

Remove the stiffener bracket.

  1. Using a T10 screwdriver, remove the M3 screws.

  2. Grasp the bracket and remove it.

    Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (95)

Step3

Remove the horizontal rear bracket.

  1. Using a T8 screwdriver, remove the M3 screws on the exterior of the IFM.

    Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (96)
  2. Using a T10 screwdriver, remove the M3 screws on the interior of the IFM.

  3. Grasp the bracket and remove it.

    Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (97)

Step4

Disconnect additional components and fasteners.

  1. Using a T8 screwdriver, remove the M3 screw on the IFM faceplate.

  2. Grasp the plastic HDMI plug and remove it.

    Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (98)
  3. Using an 8mm hexagonal nut driver, remove the standoffs.

  4. Using a T10 screwdriver, remove the M3 screws.

    Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (99)

    Red circles (Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (100) )

    M3 hexagonal standoffs, 4

    Blue circles (Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (101) )

    M3 screws, 6

  5. Grasp the PCBA and disconnect it from the sheet metal.

Step5

Disconnect the remaining components from the PCBA.

  1. Using the T10 screwdriver, remove the M3 screws for the top heatsink.

    Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (102)
  2. Turn the PCBA over so that the bottom is facing up.

  3. Using the #1 Phillips screwdriver and remove the M2 screws.

  4. Using a pliers, release the four heatsink pushpins.

    Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (103)

    Red circles (Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (104) )

    M2 screws for plastic bracket, 4

    Blue circles (Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (105) )

    Heatsink pushpins, 4

  5. Turn the PCBA over again so that the top is facing up.

  6. Grasp the plastic bracket for the M.2 module and remove it.

  7. If the top heat sink is still attached, grasp and remove it.

  8. Grasp the three fan baffles and remove them.

  9. Grasp the center heatsink and remove it.

    Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (106)

Step6

Recycle the sheet metal and motherboard in compliance with your local recycling and e-waste regulations.

What to do next

To remove the chassis motherboard, go to Recycling the Chassis PCB Assembly (PCBA).

Recycling X-Fabric Module PCBs

Each UCS X-Fabric Module has a printed circuit board (PCB) that is connected to module's sheet metal tray. To recycle each module's PCB, you must:

  • Disassemble and remove additional parts to gain access to the PCB.

  • Disconnect the PCB from the sheet metal to recycle the PCB.

  • Recycle each module in the Cisco UCS X9508 chassis.

Use the following task to recycle the X-Fabric modules.

Before you begin

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (107)

Note

For Recyclers Only! This procedure is not a standard field-service option. This procedure is for recyclers who will be reclaiming the electronics and sheet metal for proper disposal to comply with local eco design and e-waste regulations.

You will find it helpful to gather the following tools before attempting this procedure:

  • Screwdrivers: One each of T8 and T10 screwdriver

  • Nut drivers: One 8mm hexagonal head nut driver.

Procedure

Step1

Remove the following components by hand:

  1. Grasp each fan cable and remove it.

  2. Grasp each fan module and remove it.

    For information, see Removing a Fan for a UCS Intelligent Fabric Module (IFM) or X-Fabric Module (XFM) Blank.

  3. Grasp the light pipe and remove it.

    Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (108)

Step2

Remove the rear fan bracket.

  1. Using a T10 screwdriver, remove the M3 screws.

  2. Grasp the bracket and remove it.

    Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (109)

Step3

Remove the rear back-panel connector bracket.

  1. Using a T8 screwdriver, remove the M3 screws (two per side) on the exterior of the module.

    Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (110)

    Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (111)
  2. Using a T10 screwdriver, remove the M3 screws on the interior of the module.

  3. Grasp the bracket and remove it.

    Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (112)

Step4

Remove additional components and fasteners.

  1. Using an 8mm hexagonal nut driver, remove the standoffs.

  2. Using a T10 screwdriver, remove the M3 screws.

    Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (113)

    Red circles (Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (114) )

    M3 hexagonal standoffs, 4

    Blue circles (Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (115) )

    M3 screws, 4

  3. Grasp the PCBA and disconnect it from the sheet metal.

Step5

Disconnect the PCB from the sheetmetal.

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (116)

Step6

Recycle the sheet metal and motherboard in compliance with your local recycling and e-waste regulations.

What to do next

Choose the appropriate option:

  • To recycle an X-Fabric Module Blank motherboard, go to: Recycling X-Fabric Module Blank PCBs.

  • To recycle a 100G UCS Intelligent Fabric Module motherboard, go to: Recycling the UCS 9108 100G IFM PCBs.

  • To recycle a 25G UCS Intelligent Fabric Module motherboard, go to: Recycling the UCS 9108 25G IFM PCBs.

  • To recycle the chassis motherboard, go to Recycling the Chassis PCB Assembly (PCBA).

Recycling X-Fabric Module Blank PCBs

Each UCS X-Fabric Module Blank (module blank) has a printed circuit board (PCB) that is connected to module blank's sheet metal tray. To recycle each module blank's PCB, you must:

  • Disassemble and remove additional parts to gain access to the PCB.

  • Disconnect the PCB from the sheet metal to recycle the PCB.

  • Recycle each module blank in the Cisco UCS X9508 chassis.

Use the following task to recycle the module blank.

Before you begin

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (117)

Note

For Recyclers Only! This procedure is not a standard field-service option. This procedure is for recyclers who will be reclaiming the electronics and sheet metal for proper disposal to comply with local eco design and e-waste regulations.

You will find it helpful to gather a T10 screwdriver before attempting this procedure:

Procedure

Step1

Remove the following components by hand:

  1. Grasp each fan cable and remove it.

  2. Grasp each fan module and remove it.

    For information, see Removing a Fan for a UCS Intelligent Fabric Module (IFM) or X-Fabric Module (XFM) Blank.

  3. Grasp the light pipe and remove it.

    Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (118)

Step2

Grasp the fan module support bracket and remove it.

Step3

Remove the vertical rear bracket.

  1. Using a T10 screwdriver, remove the M3 screws.

  2. Grasp the bracket and remove it.

    Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (119)

Step4

Remove additional components and fasteners.

  1. Using a T10 screwdriver, remove the M3 screws.

    Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (120)

  2. Grasp the PCB and disconnect it from the sheet metal.

    Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (121)

Step5

Recycle the sheet metal and motherboard in compliance with your local recycling and e-waste regulations.

What to do next

Choose the appropriate option:

  • To recycle an X-Fabric Module motherboard, go to: Recycling X-Fabric Module PCBs.

  • To recycle a 100G UCS Intelligent Fabric Module motherboard, go to: Recycling the UCS 9108 100G IFM PCBs.

  • To recycle a 25G UCS Intelligent Fabric Module motherboard, go to: Recycling the UCS 9108 25G IFM PCBs.

  • To recycle the chassis motherboard, go to Recycling the Chassis PCB Assembly (PCBA).

Cisco UCS X9508 Server Chassis Installation Guide - Installing and Removing Components [Cisco UCS X9508 Chassis] (2024)

References

Top Articles
Latest Posts
Article information

Author: Clemencia Bogisich Ret

Last Updated:

Views: 6199

Rating: 5 / 5 (80 voted)

Reviews: 87% of readers found this page helpful

Author information

Name: Clemencia Bogisich Ret

Birthday: 2001-07-17

Address: Suite 794 53887 Geri Spring, West Cristentown, KY 54855

Phone: +5934435460663

Job: Central Hospitality Director

Hobby: Yoga, Electronics, Rafting, Lockpicking, Inline skating, Puzzles, scrapbook

Introduction: My name is Clemencia Bogisich Ret, I am a super, outstanding, graceful, friendly, vast, comfortable, agreeable person who loves writing and wants to share my knowledge and understanding with you.